Pulse Counter wrong transistion. #215

Open
voidptr69 opened this issue Nov 20, 2014 · 1 comment
Open

Pulse Counter wrong transistion. #215

voidptr69 opened this issue Nov 20, 2014 · 1 comment

Comments

@voidptr69
Copy link

Transistion counter seems display inverted result for channel1 (see pics)
for channel0 we got 1 rise 0 fall ok
for channel1 we got 0 rise 1 fall wrong ...
I did not check for other channel ...
I''m running 0.9.7 sp1

capture3
capture4

jawi pushed a commit that referenced this issue Apr 21, 2015
- fixed incorrect offsets when using cursors.
@jawi
Copy link
Owner

jawi commented Apr 21, 2015

I've committed a fix for this issue: the pulse counter was using incorrect offsets when taking the cursors into account...

jawi pushed a commit that referenced this issue Apr 21, 2015
- incorrect start & end timestamp used, the signal measurer is
  actually more precise than initially thought ;)