Expose analog inputs to HA.
The sensors show voltage in percent relative to the analog reference voltage. 0 is 0V and 100 is the analog reference voltage or above.
The analog reference voltage is 1.2V for XBee and selectable between 1.25V, 2.5V and VDD with AV command for XBee3.
The supply voltage is measured in V if enabled with V+ command.