Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

PoE design proposal HLD document #1631

Open
wants to merge 2 commits into
base: master
Choose a base branch
from
Open
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
Binary file added doc/poe/images/poe_config_flow.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file added doc/poe/images/poe_interaction.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file added doc/poe/images/poe_show_flow.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file added doc/poe/images/poe_swss_poesyncd.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file added doc/poe/images/sonic_architecture_with_poe.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
370 changes: 370 additions & 0 deletions doc/poe/poe_hld.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,370 @@
# SONiC PoE #

## Table of Content

- [Revision](#revision)
- [Scope](#scope)
- [Definition/Abbreviation](#definitions_abbreviations)
- [Overview](#overview)
- [Requirements](#requirements)
- [Architecture Design](#architecture-design)
- [PoE interaction](#poe-interaction)
- [SWSS changes](#swss-changes)
- [PoE SYNCD](#poe-syncd)
- [PoE Manager](#poe-manager)
- [LLDP Manager](#lldp-manager-modified)
- [High-Level Design](#high-level-design)
- [PoE flows](#poe-flows)
- [PoE data collection](#poe-data-collection)
- [PoE configuration](#poe-configuration)
- [SAI API](#sai-api)
- [PoE AI](#poe-abstraction-interface)
- [Configuration and management](#configuration-and-management)
- [CLI/YANG model Enhancements](#cli_yang-model-enhancements)
- [Show commands](#show-commands)
- [Config commands](#config-commands)
- [Config DB Enhancements](#config-db-enhancements)
- [State DB Enhancements](#state-db-enhancements)
- [Restrictions/Limitations](#restrictions_limitations)

### Revision

| Rev | Date | Author | Change Description |
|:---:|:----:|:--------------:|--------------------|
| 0.1 | 03-26-2024 | Volodymyr Mytnyk | Initial version |
| 0.2 | 04-01-2024 | Volodymyr Mytnyk | Add SWSS cahnges, include LLDP interaction, add example PoE config, mention about warm reboot requirements |

### Scope

This document provides general information about the PoE (Power over Ethernet) feature implementation in SONiC.

### Definitions/Abbreviations

| | |
|--------------------------|--------------------------------|
| PoE | Power over Ethernet |

### Overview

Ethernet switch (e.g. campus specific platforms) today often comes with Power over Ethernet (PoE) feature support. PoE functioalility itself is considered as an external functionality from NPU SAI/SDK point of view as it is configurable via external PoE controller.


### Requirements

- PoE feature can be enabled via compile option (disabled by default);
- PoE config persistence during SONiC reboot;
- Support CLI configurations as mentioned in [config section](#config-commands) and [show section](#show-commands);
- LLDP support (PoE power reporting only, future releases);
- Warm boot;

### Architecture Design

In order to isolate PoE functionality and complexity from existing SONiC design, the following main changes are made:

- Add separate container for PoE control plane routine configuration.

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

How this design address the platform dependencies?
Since there is a separate docker/container for the PoE, How this can resolve the platform dependencies like the dynamic detection of PSU and their power budget etc.

- Introduce separate SYNCD container to support external PoE Abstraction Interface.
- Add new PoE tables into database container.

The following diagram explains the changes needed in existing SONiC architecture.

![poe-changes](images/sonic_architecture_with_poe.png)

#### PoE interaction

This section describes the detail interaction of PoE componnents, DB and PoE hardware (controller) in SONiC subsytem.

![poe-interaction](images/poe_interaction.png)

#### SWSS changes

In case to support external and separate PoE SAI, and following SONiC architecture design, SWSS container needs to be extended
with PoE orch deamon that will handle all PoE ASIC DB requests and does PoE initialization.

![swss-changes](images/poe_swss_poesyncd.png)

#### PoE SYNCD

New PoE SYNCD container componnents:
Copy link
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

what is the reason to have a poe syncd? why normal syncd won't work. isn't that poe feature is captured with SAI api, then normal syncd can support poe as long as the sai library support poe?

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

I believe the motivation is to allow use of an additional instance of SAI. one for NPU and one for PoE. This is assuming that NPU and PoE HW and drivers are developed by different vendors

- *poesyncd* - syncd poe configuration between db and poe pse devices
- *poe sai api* - PoE Abstraction interface to configure PoE controller (see [PoE AI section](#poe-abstraction-interface))
- *poe library*- library that has low level poe logic and the transportation to and from the hardware

##### PoE library

The PoE library has lower level PoE software logic, and the transportation to and from the PoE hardware. This includes reading and/or writing PoE information such as power consumption, PSE temperatures, port status, port admin state and more.
As long as the library supports the saipoe.h file, it can be changed per board/vendor, and the functionality will stay the same.

#### PoE manager

PoE manager consists of a daemon that implements the following functionality:

- Making sure that the PSEs are functional;
- Collect variable PoE data periodically;
- PoE status;
- PoE protocol and class;
- PoE power, current and voltage;
- PSE information;
- apply PoE controller configuration;
- track changes in config, appl DB;

##### Configuration

Below is a example of PoE configuration used by PoE manager on start up. The mapping between PoE port and ASIC port is done via front panel id.
```
{
"hw_info": "integrated_mcu",
"pse_list": [
{
"pse_index": 0
},
{
"pse_index": 1
},
...
],
"port_mapping_list": [
{
"Ethernet0":
{
"front_panel_index": 1
},
...
"Ethernet47":
{
"front_panel_index": 48
}
}
]
}
```

#### LLDP manager (modified)

To exchange the PoE information with peer about power supply capability, the LLDP protocol is used. In case to support
that, LLDP manager is required to be modified as following:

- LLDP manager gets PoE information (from application PoE database).
- LLDP manager adds LLDP TLV with PoE information into LLDP packet.
- LLDP negotiation (future versions).

### High-Level Design

This section covers the high level design of the built-in SONiC PoE feature.

This section covers the following points in detail.

- Existing moduels are not modified by this design.
- Repositories that will be changed: sonic-buildimage, ...
- Module/sub-module interfaces and dependencies.
- SWSS and Syncd are not changed.
- This design doesn't change existing DB Schema, only new are added.
- Linux dependencies and interface
- Fastboot requirements & dependencies
- Scalability and performance requirements/impact
- Memory requirements
- Docker dependency
- Build dependency if any
- Management interfaces - SNMP, CLI, RestAPI, etc.,
- Serviceability and Debug (logging, counters, trace etc) related design
- Is this change specific to any platform? Are there dependencies for platforms to implement anything to make this feature work? If yes, explain in detail and inform community in advance.
- SAI API requirements, CLI requirements, ConfigDB requirements. Design is covered in following sections.

##### PoE flows

###### PoE data collection

"Show" flow:
1. Get PoE controller information;
2. Update application DB with the PoE status;
3. Repeat step 1-2 each seconds (optional);
4. SONiC CLI read and display PoE infomation from application DB;

![sequence_show_command](images/poe_show_flow.png)

###### PoE configuration

Configuration flow:
1. Configure PoE using SONiC CLI;
2. Update Config DB accordingly;
3. Poemgrd subscribe to related tables in Config DB;
4. Call PoE AI for related configuration;

![sequence_cfg_command](images/poe_config_flow.png)


### SAI API

- SAI object types extended to support PoE
- SAI API list is extended to supprot PoE
- New PoE switch type added

### PoE Abstraction Interface

The PoE Manager uses a new SAI PoE library that implements the PoE Abstraction Interface.
Copy link
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

can you share the poe sai library pr? is it already merged in sai?

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

SAI PR -opencomputeproject/SAI#1977 (merged)
Implementation will be (PoE HW) vendor specific, we will be providing an example, working implementation for MicroChip PSE (in development)


#### Device Capabilities

| Capabilities | SAI attributes |
| ----------------- | ------------------------------------- |
| Hardware Info | SAI_POE_DEVICE_ATTR_HARDWARE_INFO |
| PSE List | SAI_POE_DEVICE_ATTR_POE_PSE_LIST |
| PoE List | SAI_POE_DEVICE_ATTR_POE_PORT_LIST |
| Total Power | SAI_POE_DEVICE_ATTR_TOTAL_POWER |
| Power Consumption | SAI_POE_DEVICE_ATTR_POWER_CONSUMPTION |
| Version | SAI_POE_DEVICE_ATTR_VERSION |
| Power Limit Mode | SAI_POE_DEVICE_ATTR_POWER_LIMIT_MODE |


#### PSE Capabilities

| Capabilities | SAI attributes |
| --------------- | ------------------------------------- |
| PSE ID | SAI_POE_PSE_ATTR_ID |
| PSE SW Version | SAI_POE_PSE_ATTR_PSE_SOFTWARE_VERSION |
| PSE HW Version | SAI_POE_PSE_ATTR_PSE_HARDWARE_VERSION |
| PSE Temperature | SAI_POE_PSE_ATTR_TEMPERATURE |
| PSE Status | SAI_POE_PSE_ATTR_PSE_STATUS |

#### Port Capabilities

| Capabilities | SAI attributes |
| ------------------ | ------------------------------------- |
| Front Panel ID | SAI_POE_PORT_ATTR_FRONT_PANEL_ID |
| Standard | SAI_POE_PORT_ATTR_STANDARD |
| Admin Enable State | SAI_POE_PORT_ATTR_ADMIN_ENABLED_STATE |
| Power Limit | SAI_POE_PORT_ATTR_POWER_LIMIT |
| Power Priority | SAI_POE_PORT_ATTR_POWER_PRIORITY |
| Power Consumption | SAI_POE_PORT_ATTR_CONSUMPTION |
| Status | SAI_POE_PORT_ATTR_STATUS |
| Detailed Status | SAI_POE_PORT_ATTR_DETAILED_STATUS |


### Configuration and management

#### Manifest (if the feature is an Application Extension)
Feature is not an Application Extension

#### CLI

##### Show commands
- show poe status

```
PoE system information
================================
Status : ready
Total PoE Ports : 48

Total Power : 714.500 W
Power Consumption : 12.500 W
Power Available : 702.000 W

```

- show poe interface \<ifname\>
```

Port Status En/Dis Priority Protocol Class PWR Consump PWR Limit Voltage Current
------------ ----------- ------- -------- ------------- ----- ------------ ---------- --------- ---------
Ethernet0 delivering enable high 802.3BT/High 4 6.100 W 80.600 W 54.000 V 0.113 A
Ethernet1 delivering enable crit 802.3BT/High 4 6.500 W 80.600 W 54.000 V 0.120 A
Ethernet2 searching enable low 802.3BT/High 0 0.000 W 80.600 W 0.000 V 0.000 A
Ethernet3 searching enable crit 802.3BT/High 0 0.000 W 80.600 W 0.000 V 0.000 A
```

##### Config commands

- config poe interface status \<ifname\> {enable | disable}
- config poe interface priority \<ifname\> {crit | high | low}
- config poe interface power_limit \<ifname\> {power_limit}

Examples:
```
$ config poe interface status Ethernet0 enable
$ config poe interface priority Ethernet0 high
$ config poe interface power_limit Ethernet0 20.4
```

**TODO**: update CLI reference https://github.com/sonic-net/sonic-utilities/blob/master/doc/Command-Reference.md

#### YANG model Enhancements

TBD

#### Config DB Enhancements

New table has been added to the config database to store related PoE configuration parameters:

##### POE_PORT_TABLE
~~~
;Stores PoE port configuration
key = POE_PORT|ifname ; ifname with prefix POE_PORT
; field = value
enabled = "enable" / "disable" ; enable/disable PoE on port, default "disable"
power_limit = 1*3.1DIGIT ; power limit on PoE port

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Please confirm whether power budget will get updated when the PSU gets removed from the switch. Whether this will be taken care by the hardware ?

priority = "crit" / "high" / "low" ; port priority level, default "high"
~~~

#### Application DB Enhancements

In SONiC all the peripheral devices data (information relared to PoE) will be stored in application database in separated tables:

#### POE_PSE_STATE_TABLE
~~~
; Defines information for a global PoE state
key = POE_TABLE:GLOBAL ; key
; field = value
platform_supported = BOOLEAN ; PoE platform support
poe_status = "N/A" / "init" / "failed" / "ready" ; PoE status
total_ports = 1*2DIGIT ; total PoE ports
total_pwr = 1*4.3DIGIT ; total power
pwr_consump = 1*4.3DIGIT ; total power consumption
pwr_avail = 1*4.3DIGIT ; available power
pse_sw_ver = STRING ; PSE software version
pse_hw_ver = STRING ; PSE hardware version
pse_temp = 1*3DIGIT ; PSE temperature
pse_status = "active" / "fail" / "not present" ; PSE status
~~~

#### POE_PORT_STATE_TABLE
; Defines information for a PoE port state
key = POE_PORT_STATE|ifname ; ifname with prefix POE_PORT_STATE
; field = value
fp_port = 1*2DIGIT ; PoE front panel port (map PoE port num to ifname)
status = BOOLEAN ; presence state of the PoE
enabled = "enable" / "disable" ; PoE enabled on port
priority = "crit" / "high" / "low" ; port priority level
protocol = STRING ; name of PoE protocol
class = 1*DIGIT ; power class
pwr_consump = 1*3.3DIGIT ; the power of the PoE
pwr_limit = 1*3.3DIGIT ; power capacity of the PoE port
voltage = 1*3.3DIGIT ; output voltage of the PoE port
current = 1*3.3DIGIT ; the current of the PoE port


### Warmboot and Fastboot Design Impact

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Please capture if we are planning to support persistent supply of power to PD from PSE during reboot.


In scope of current desgin, the PoE functionality should continue to work across warm boot. The PoE configuration is present in the ASIC database and therefore should be compatible with existing SYNCD and its warm boot capabilities.

### Memory Consumption
This sub-section covers the memory consumption analysis for the new feature: no memory consumption is expected when the feature is disabled via compilation and no growing memory consumption while feature is disabled by configuration.

### Restrictions/Limitations

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Can you please confirm if we support Legacy PDs ? If not please capture them in Limitations


### Testing Requirements/Design

Testing of PoE functionality are covered by unit & system testing.

#### Unit Test cases

PoE components (like PoE syncd, REDIS API) can be validated and covered by mocking PoE SAI API. The existing syncd unit tests can be extended to cover PoE functionality.

#### System Test cases

System testing can be done only on systems with PoE hardware support.

TBD

### Open/Action items