# This is a sample Python script.
# Press Mayús+F10 to execute it or replace it with your code.
# Press Double Shift to search everywhere for classes, files, tool windows, actions, and settings.
import time
from fileUtilities import readConfigFile
from pymeasure.adapters import VISAAdapter
from pymeasure.instruments.eurotest.eurotestHPP120256 import EurotestHPP120256
from pymeasure.instruments.keithley import Keithley2400
def check_presence(inst):
response = inst.id
print(response)
time.sleep(1)
def getInstruments(k2400_gpibAddress, hvSource_gpibAddress):
hpp120256 = None
k2400 = None
hpp120256_adapter = VISAAdapter("GPIB0::"+str(hvSource_gpibAddress)+"::INSTR",
write_termination="\n",
read_termination="",
send_end=True)
hpp120256_adapter.connection.timeout = 5000
response_encoding = "iso-8859-2" # In my case, instrument uses this encoding on response, so take it into account
query_delay = 0.2 # Delay in s to sleep between the write and read occuring in a query
hpp120256 = EurotestHPP120256(hpp120256_adapter, response_encoding, query_delay, includeSCPI=False)
check_presence(hpp120256)
k2400_adapter = VISAAdapter("GPIB0::" + str(k2400_gpibAddress) + "::INSTR",
write_termination="\n",
read_termination="",
send_end=True)
k2400 = Keithley2400(k2400_adapter)
check_presence(k2400)
return k2400, hpp120256
def initializeK2400(k2400, compliance, nplcs, range):
pass
def initializeHVSource(hv_source, rampVoltage, outputCurrentLimit, enableKill):
pass
def start_process(K2400_gpibAddress,
HVSource_gpibAddress,
initialVoltage,
finalVoltage,
pointsVoltage,
measureDelay_ms,
rampVoltage,
outputCurrentLimit,
enableKill,
ammeterRange,
ammeterCompliance,
ammeterNPLCs,
resultsFilePath):
k2400, hv_source = getInstruments(K2400_gpibAddress, HVSource_gpibAddress)
# Press the green button in the gutter to run the script.
if __name__ == '__main__':
process_config_file_path = "process_config_file.json"
dut_reference = ""
K2400_gpibAddress, \
HVSource_gpibAddress, \
initialVoltage, \
finalVoltage, \
pointsVoltage, \
measureDelay_ms, \
rampVoltage, \
outputCurrentLimit, \
enableKill, \
ammeterRange, \
ammeterCompliance, \
ammeterNPLCs, \
resultsFilePath, \
resultsFilePathExtension = readConfigFile(process_config_file_path)
start_process(K2400_gpibAddress,
HVSource_gpibAddress,
initialVoltage,
finalVoltage,
pointsVoltage,
measureDelay_ms,
rampVoltage,
outputCurrentLimit,
enableKill,
ammeterRange,
ammeterCompliance,
ammeterNPLCs,
resultsFilePath + str(dut_reference) + "." + resultsFilePathExtension)