OpenTherm.h
318 lines (283 loc) · 16.9 KB
/
OpenTherm.h
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
/*
OpenTherm.h - OpenTherm Library for the ESP8266/Arduino platform
https://github.com/ihormelnyk/OpenTherm
http://ihormelnyk.com/pages/OpenTherm
Licensed under MIT license
Copyright 2018, Ihor Melnyk
Updated by raf1000 in relation to "Brink Renovent HR"
Frame Structure:
P MGS-TYPE SPARE DATA-ID DATA-VALUE
0 000 0000 00000000 00000000 00000000
*/
#ifndef OpenTherm_h
#define OpenTherm_h
#include <stdint.h>
#include <Arduino.h>
enum OpenThermResponseStatus {
NONE,
SUCCESS,
INVALID,
TIMEOUT
};
enum OpenThermMessageType {
/* Master to Slave */
READ_DATA = B000,
READ = READ_DATA, // for backwared compatibility
WRITE_DATA = B001,
WRITE = WRITE_DATA, // for backwared compatibility
INVALID_DATA = B010,
RESERVED = B011,
/* Slave to Master */
READ_ACK = B100,
WRITE_ACK = B101,
DATA_INVALID = B110,
UNKNOWN_DATA_ID = B111
};
typedef OpenThermMessageType OpenThermRequestType; // for backwared compatibility
enum OpenThermMessageID {
Status, // flag8 / flag8 Master and Slave Status flags.
TSet, // f8.8 Control setpoint ie CH water temperature setpoint (°C)
MConfigMMemberIDcode, // flag8 / u8 Master Configuration Flags / Master MemberID Code
SConfigSMemberIDcode, // flag8 / u8 Slave Configuration Flags / Slave MemberID Code
Command, // u8 / u8 Remote Command
ASFflags, // / OEM-fault-code flag8 / u8 Application-specific fault flags and OEM fault code
RBPflags, // flag8 / flag8 Remote boiler parameter transfer-enable & read/write flags
CoolingControl, // f8.8 Cooling control signal (%)
TsetCH2, // f8.8 Control setpoint for 2e CH circuit (°C)
TrOverride, // f8.8 Remote override room setpoint
TSP, // u8 / u8 Number of Transparent-Slave-Parameters supported by slave
TSPindexTSPvalue, // u8 / u8 Index number / Value of referred-to transparent slave parameter.
FHBsize, // u8 / u8 Size of Fault-History-Buffer supported by slave
FHBindexFHBvalue, // u8 / u8 Index number / Value of referred-to fault-history buffer entry.
MaxRelModLevelSetting, // f8.8 Maximum relative modulation level setting (%)
MaxCapacityMinModLevel, // u8 / u8 Maximum boiler capacity (kW) / Minimum boiler modulation level(%)
TrSet, // f8.8 Room Setpoint (°C)
RelModLevel, // f8.8 Relative Modulation Level (%)
CHPressure, // f8.8 Water pressure in CH circuit (bar)
DHWFlowRate, // f8.8 Water flow rate in DHW circuit. (litres/minute)
DayTime, // special / u8 Day of Week and Time of Day
Date, // u8 / u8 Calendar date
Year, // u16 Calendar year
TrSetCH2, // f8.8 Room Setpoint for 2nd CH circuit (°C)
Tr, // f8.8 Room temperature (°C)
Tboiler, // f8.8 Boiler flow water temperature (°C)
Tdhw, // f8.8 DHW temperature (°C)
Toutside, // f8.8 Outside temperature (°C)
Tret, // f8.8 Return water temperature (°C)
Tstorage, // f8.8 Solar storage temperature (°C)
Tcollector, // f8.8 Solar collector temperature (°C)
TflowCH2, // f8.8 Flow water temperature CH2 circuit (°C)
Tdhw2, // f8.8 Domestic hot water temperature 2 (°C)
Texhaust, // s16 Boiler exhaust temperature (°C)
TdhwSetUBTdhwSetLB = 48, // s8 / s8 DHW setpoint upper & lower bounds for adjustment (°C)
MaxTSetUBMaxTSetLB, // s8 / s8 Max CH water setpoint upper & lower bounds for adjustment (°C)
HcratioUBHcratioLB, // s8 / s8 OTC heat curve ratio upper & lower bounds for adjustment
TdhwSet = 56, // f8.8 DHW setpoint (°C) (Remote parameter 1)
MaxTSet, // f8.8 Max CH water setpoint (°C) (Remote parameters 2)
Hcratio, // f8.8 OTC heat curve ratio (°C) (Remote parameter 3)
// Ventilation Specific Message IDs
VentStatus = 70, // flag8 / flag8 Master and Slave Status flags specific to Vent systems, READ STATUS V/H , HB0-HB3,LB0-LB5
VentNomVentSet, // _ / u8 Set the relative ventilation 0-100%, WRITE, CONTROL SETPOINT V/H
VentFault, // flag8 / flag8 Application specific fault flags, READ (u8) FAULT FLAGS/CODE V/H
VentOEMFault, // flag8 / flag8 Oem specific fault flags, DIAGNOSTIC CODE V/H,READ,U16
VentSlaveVentConfig = 74, // Slave Configuration Flags / Slave MemberID Code, CONFIG/MEMBERID V/H,READ,U8 , HB0-HB2, LB
VentOTversion, // f8.8 OPENTHERM VERSION V/H,READ, 0,127,“2,32”,Yes
VentVersionType, // VERSION & TYPE V/H,READ,U8,0,255,1,U8,0,255,0,Yes
VentNomVent = 77, // _ / u8 Read the relative ventilation 0-100%, RELATIVE VENTILATION,READ,U8,0,255
VentRelHumid, // _ / u8 Read the relative humidity 0-100%, RELATIVE HUMIDITY,READ,U8,0,255, RELATIVE HUMIDITY,WRITE,U8,0,255
VentCO2level, // u16 CO2 level in PPM (0-2000), CO2 LEVEL,READ,U16,0,10000 , CO2 LEVEL,WRITE,U16,0,10000
VentTsupplyin, // f8.8 Supply Outlet temperature SUPPLY INLET TEMPERATURE,READ,F8.8,0,127,“0,00”
VentTsupplyout, // f8.8 Supply Outlet temperature SUPPLY OUTLET TEMPERATURE,READ,F8.8,0,127,“0,00”
VentTexhaustin,// f8.8 Exhaust Inlet temperature EXHAUST INLET TEMPERATURE,READ,F8.8,0,127,“0,00”
VentTexhaustout, // f8.8 Exhaust Outlet temperature EXHAUST OUTLET TEMPERATURE,READ,F8.8,0,127,“0,00"
VentRPMexhaust, // u16 Actual RPM for inlet fan ACTUAL EXHAUST FAN SPEED,READ,U16,0,10000
VentRPMsupply, // u16 Actual RPM for supply fan ACTUAL INLET FAN SPEED”,READ,U16,0,10000
VentRemoteParam, // REMOTE PARAMETER SETTINGS V/H,READ,FLAG, HBO, LBO
VentNomRelVent = 87, // _ / u8 Get the current relative ventilation NOMINAL VENTIALTION VALUE,READ,U8,0,255, NOMINAL VENTIALTION VALUE,WRITE,U8,0,255
VentTSPNumber, // TSP NUMBER V/H,READ,U8,0,255,0,U8
VentTSPEntry, // TSP ENTRY V/H,READ,U8,0,255,0,U8,0,255 TSP ENTRY V/H,WRITE,U8,0,255,0,U8,0,255
VentFaultBufferSize, // FAULT BUFFER SIZE V/H ,READ,U8,0,255,0,U8,0,0,
VentFaultBufferEntry, // FAULT BUFFER ENTRY V/H READ,U8,0,255,0,U8,0,255
RemoteOverrideFunction = 100, // flag8 / - Function of manual and program changes in master and remote room setpoint.
OEMDiagnosticCode = 115, // u16 OEM-specific diagnostic/service code
BurnerStarts, // u16 Number of starts burner
CHPumpStarts, // u16 Number of starts CH pump
DHWPumpValveStarts, // u16 Number of starts DHW pump/valve
DHWBurnerStarts, // u16 Number of starts burner during DHW mode
BurnerOperationHours, // u16 Number of hours that burner is in operation (i.e. flame on)
CHPumpOperationHours, // u16 Number of hours that CH pump has been running
DHWPumpValveOperationHours, // u16 Number of hours that DHW pump has been running or DHW valve has been opened
DHWBurnerOperationHours, // u16 Number of hours that burner is in operation during DHW mode
OpenThermVersionMaster, // f8.8 The implemented version of the OpenTherm Protocol Specification in the master.
OpenThermVersionSlave, // f8.8 The implemented version of the OpenTherm Protocol Specification in the slave.
MasterVersion, // u8 / u8 Master product version number and type
SlaveVersion, // u8 / u8 Slave product version number and type
};
enum OpenThermStatus {
NOT_INITIALIZED,
READY,
DELAY,
REQUEST_SENDING,
RESPONSE_WAITING,
RESPONSE_START_BIT,
RESPONSE_RECEIVING,
RESPONSE_READY,
RESPONSE_INVALID
};
// Brink Renovent HR specific codes
enum BrinkTSPindex {
U1, // Volume Step 1 - 2 bytes
U2 = 2, // Volume Step 2 - 2 byts
U3 = 4, // Volume Step 3 - 2 bytes
U4 = 6, // Minimum atmospheric temperature bypass (value multiplied *2, ex 15C <=> 30)
U5 = 7, // Minimum indor temperature bypass (value multiplied *2)
U6, // option PCB: postheater temp seting, control postheater up to 1000 W
U7, // option PCB: proportional input mode (ex moisture sensor, CO2 sensor): A = only 3-way switch, b = proportional input 1, C = proportional input 2, d = proportional input 1 and proportional input 2 (input 1 precedes input 2)
U8, // Not applicable
I1, // Fixed imbalance (value shifted by 100, ex 100 <=> 0)
I2, // No contact step
I3, // not applicable
I4, // Switch line step 1
I5, // Switch line step 2
I6, // Switch line step 3
I7, // Imbalance permissible
I8, // Bypass mode
I9, // Hysteresis bypass
I10, // Constand pressure switched off
I11, // Preheater (0-3), o = no preheater
I12, // Offset temperature preheater(value shifted by 60, 60 <=> 0, 61 <=> 0.5)
I13, // Filter message on/off (1=on)
I14, // Option PCB present (0 = no)
I15, // Heat recovery configuration (0=heat recovery, 1 = central heating + heat recovery)
I16, // Fan setting for central heating + heat recovery
I17, // Repeat time in hours for switching off the fan(s) selected under I16
I18, // Maximum switch-off time in seconds for the fan(s) selected under I16
I19, // Minimum switch-off time in seconds for the fan(s) selected under I16
P1 = 31,// option PCB: air volume of the supply volume in case of emergency
P2, // option PCB: air volume of the exhaust fan in case of emergency
P3, // option PCB: additional air volume supply fan when bedroom valve entrance is closed (this volume is added to the volume related to 3 way switch)
P4, // option PCB: additional air volume exhaust fan when bedroom valve entrance is closed
P5, // option PCB: programmable make contact 1, indicates where make contact 1 should be connected, 0 = not linked, 1 = overrule frost control, 2 = link to bypass conditions, 3 = link to frost conditions, 4 = bypass valve control
P6, // option PCB: programmable make contact 1, determines how the supply fan reacts when make contact 1 is made: 0 = volume to absolute minimum, 1 = volume according to 3-way switch setting, 2 = volume according to position 3 of the 3-way switch, 3 = fan off
P7, // option PCB: programmable make contact 1, determines how the exhaust fan reacts when make contact 1 is made: 0 = volume to absolute minimum, 1 = volume according to 3-way switch setting, 2 = volume according to position 3 of the 3-way switch, 3 = fan off
P8, // option PCB: programmable make contact 2, indicates where make contact 1 should be connected, 0 = not linked, 1 = overrule frost control, 2 = link to bypass conditions, 3 = link to frost conditions, 4 = bypass valve control
P9, // option PCB: programmable make contact 2, determines how the supply fan reacts when make contact 1 is made: 0 = volume to absolute minimum, 1 = volume according to 3-way switch setting, 2 = volume according to position 3 of the 3-way switch, 3 = fan off
P10, // option PCB: programmable make contact 2, determines how the exhaust fan reacts when make contact 1 is made: 0 = volume to absolute minimum, 1 = volume according to 3-way switch setting, 2 = volume according to position 3 of the 3-way switch, 3 = fan off
P11, // option PCB: determines the target voltage of the proportional input 1 (moisture sensor) 0-10V . The volume control tries to adjust the input voltage to the target voltage within the set conditions.
P12, // option PCB: gives the maximum voltage of the device connected to the proportional input 1 (moisture sensor),tThe proportional band of the PI controller is automatically adjusted.
P13, // option PCB: defines the integration time of the PI controller from the proportional input 1 (moisture sensor). The PI controller controls pure proportional if the integration time is 0 second.
P14, // option PCB: determines the target voltage of the proportional input 2 (CO2 sensor) 0-10V . The volume control tries to adjust the input voltage to the target voltage within the set conditions.
P15, // option PCB: gives the maximum voltage of the device connected to the proportional input 2 (CO2 sensor),tThe proportional band of the PI controller is automatically adjusted.
P16, // option PCB: defines the integration time of the PI controller from the proportional input 2 (Co2 sensor). The PI controller controls pure proportional if the integration time is 0 second.
P17, // option PCB: control preheater up to 1000 W, 0 = no preheater, 1 = preheater present
MaxVol, // Maximum avilable volume [m3/h] - in/out - 2 bytes
MinVol = 50, //Minimum allowed volume (50m3/h for HR Large) - 2 bytes
CurrentVol = 52, // Current position/outlet volume [m3/h]
MsgOperation, //?Message code operating conditions: C0 = no messages, C3 = input fan runs in constant pressure, C6 = output fan runs in constand pressure, C7 = correction max air flaw, C8 = imbalance, C12 = emergency mode
BypassStatus, // Bypass status 0=bypass valve shut, 1 = bypass valve automatic, 2 = inpute at minimum
TempAtmo, // Temperature from atmosphere [°C] (shifted by 100)
TempIndoors, // Temperature from indors [°C] (shifted by 100)
InitStatus, // 1 = aplliance initiated, 0 = not initiated
VoltageParam1, // option PCB: voltage on proportional input 1 (moisture sensor) 0-10V
VoltageParam2, // option PCB: voltage on proportional input 2 (CO2 sensor) 0-10V
CurrentInputVol, //Current input volume [m3/h] - 2 bytes
CurrentOutputVol = 62, //Current output volume [m3/h] - 2 bytes
CPID = 64, // Current pressure input duct [Pa] - 2 bytes
CPOD = 66, // Current pressure output duct [Pa] - 2 bytes
FrostStatus = 68,// ?Status frost protection: 0 = none, 1-4 = imbalance, 5 = input fan off
Temp2Atmo, // ?Temperature to atmosphere, sensor not connected as standard [°C] (shifted by 100)
Temp2Indoors, // ?Temperature to indoors, sensor not connected as standard [°C] (shifted by 100)
TempPostHeater, // ?Temperature postheater 0 = 0°C (not active)
};
class OpenTherm
{
public:
OpenTherm(int inPin = 4, int outPin = 5, bool isSlave = false);
volatile OpenThermStatus status; //zdefiniowanie zminnej wspoldzielonej z ICHACHE
void begin(void(*handleInterruptCallback)(void));
void begin(void(*handleInterruptCallback)(void), void(*processResponseCallback)(unsigned long, OpenThermResponseStatus));
bool isReady();
unsigned long sendRequest(unsigned long request);
bool sendResponse(unsigned long request);
bool sendRequestAync(unsigned long request);
unsigned long buildRequest(OpenThermMessageType type, OpenThermMessageID id, unsigned int data);
unsigned long buildResponse(OpenThermMessageType type, OpenThermMessageID id, unsigned int data);
OpenThermResponseStatus getLastResponseStatus();
const char *statusToString(OpenThermResponseStatus status);
void handleInterrupt();
void process();
void end();
bool parity(unsigned long frame);
OpenThermMessageType getMessageType(unsigned long message);
OpenThermMessageID getDataID(unsigned long frame);
const char *messageTypeToString(OpenThermMessageType message_type);
bool isValidRequest(unsigned long request);
bool isValidResponse(unsigned long response);
//requests
unsigned long buildSetBoilerStatusRequest(bool enableCentralHeating, bool enableHotWater = false, bool enableCooling = false, bool enableOutsideTemperatureCompensation = false, bool enableCentralHeating2 = false);
unsigned long buildSetBoilerTemperatureRequest(float temperature);
unsigned long buildGetBoilerTemperatureRequest();
//responses
bool isFault(unsigned long response);
bool isCentralHeatingActive(unsigned long response);
bool isHotWaterActive(unsigned long response);
bool isFlameOn(unsigned long response);
bool isCoolingActive(unsigned long response);
bool isDiagnostic(unsigned long response);
uint16_t getUInt(const unsigned long response) const;
float getFloat(const unsigned long response) const;
unsigned int temperatureToData(float temperature);
// Brink renovent HR
uint8_t getU8 (const unsigned long response) const;
//basic requests
unsigned long setBoilerStatus(bool enableCentralHeating, bool enableHotWater = false, bool enableCooling = false, bool enableOutsideTemperatureCompensation = false, bool enableCentralHeating2 = false);
bool setBoilerTemperature(float temperature);
float getBoilerTemperature();
float getReturnTemperature();
bool setDHWSetpoint(float temperature);
float getDHWTemperature();
float getModulation();
float getPressure();
unsigned char getFault();
//Ventilation systems requests
unsigned int getVentilation();
unsigned int setVentilation(unsigned int nominal_value);
float getVentSupplyInTemperature();
float getVentSupplyOutTemperature();
float getVentExhaustInTemperature();
float getVentExhaustOutTemperature();
//Brink Renovent HR
bool getFaultIndication();
bool getVentilationMode();
bool getBypassStatus(); // does not work
bool getBypassAutomaticStatus(); // does not work
bool getDiagnosticIndication();
bool getBypassPosition(); // does not work
bool getBypassMode(); // does not work
//Brink Renovent HR
uint8_t getBrinkTSP(BrinkTSPindex index) ;
bool setBrinkTSP(BrinkTSPindex index, uint8_t value);
unsigned int getVentRPM(OpenThermMessageID id);
uint8_t getVentFaultCode();
bool setBrink2TSP(BrinkTSPindex first_index, uint16_t value);
uint16_t getBrink2TSP(BrinkTSPindex first_index);
private:
const int inPin;
const int outPin;
const bool isSlave;
volatile unsigned long response;
volatile OpenThermResponseStatus responseStatus;
volatile unsigned long responseTimestamp;
volatile byte responseBitIndex;
int readState();
void setActiveState();
void setIdleState();
void activateBoiler();
void sendBit(bool high);
void(*handleInterruptCallback)();
void(*processResponseCallback)(unsigned long, OpenThermResponseStatus);
};
#ifndef ICACHE_RAM_ATTR
#define ICACHE_RAM_ATTR
#endif
#endif // OpenTherm_h