States for PSTREAM

version: 1.0.0

inverter_heartbeat

energy

inverter_heartbeat

number

State Min Max Unit Mult Name
pv1InputVolt 0 60 V 0.1 PV1 input voltage
pv1OpVolt 0 62 V 0.01 PV1 operation voltage
pv1InputCur 0 13 A 0.1 PV1 input current
pv1InputWatts 0 600 W 0.1 PV1 input power
pv1Temp 0 80 °C 0.1 PV1 mppt temperature
pv2InputVolt 0 60 V 0.1 PV2 input voltage
pv2OpVolt 0 62 V 0.01 PV2 operation voltage
pv2InputCur 0 13 A 0.1 PV2 input current
pv2InputWatts 0 600 W 0.1 PV2 input power
pv2Temp 0 80 °C 0.1 PV2 mppt temperature
batInputVolt 0 60 V 0.1 Battery input voltage
batOpVolt 0 62 V 0.1 Battery operation voltage
batInputCur 0 20 A 0.001 Battery input current
batInputWatts 0 800 W 0.1 Battery input power
batTemp 0 90 °C 0.1 Battery temperature
batSoc 0 100 % 1 Battery state of charge
llcInputVolt 0 65 V 0.1 Converter input voltage
llcOpVolt 0 62 V 0.01 Converter operation voltage
llcTemp 0 80 °C 0.1 Converter temperature
invInputVolt 0 60 V 0.01 Inverter DC input voltage
invOpVolt 0 250 V 0.1 Inverter AC output voltage
invOutputCur 0 20 A 0.001 Inverter AC output current
invOutputWatts 0 800 W 0.1 Inverter AC power
invTemp 0 80 °C 0.1 Inverter temperature
invFreq 0 52 Hz 0.1 Inverter AC frequency
invDcCur 0 20 A 0.001 Inverter DC input current
heartbeatFrequency 0 20 Hz 1 Inverter heartbeat
dynamicWatts 0 10000 W 0.1 Dynamic Power
batChargingTime 0 144000 min 1 Battery Charging Time
batDischargingTime 0 144000 min 1 Battery Discharging Time

level

State Min Max Unit Mult Name cmd
permanentWatts 0 600 W 0.1 Permanent Power {cmdFunc:20,cmdId:129,dataLen:3}
ratedPower 0 600 W 0.1 Inverter rated power {cmdFunc:20,cmdId:146,dataLen:3}
lowerLimit 0 30 % 1 Battery SOC lower limit {cmdFunc:20,cmdId:132,dataLen:2}
upperLimit 50 100 % 1 Battery SOC upper limit {cmdFunc:20,cmdId:133,dataLen:2}
invBrightness 0 100 % 0.1 Inverter brightness {cmdFunc:20,cmdId:135,dataLen:3}

switch

State off on Name cmd
supplyPriority supply prio charge prio Supply Priority {cmdFunc:20,cmdId:130,dataLen:2}
feedPriority all sun to power only permanent watt Excessive Power Feed Priority {cmdFunc:20,cmdId:143,dataLen:2}

diagnostic

State Name values
invErrCode Inverter Error Code {0:OK,8:high voltage?,72:no voltage?,4096:no voltage,4160:4160,8192:8192,12288:12288}
invWarnCode Inverter Warning Code {0:0}
pv1ErrCode PV1 Error Code {0:0,128:128,130:130,256:256,384:384}
pv1WarnCode PV1 Warning Code {0:0}
pv2ErrCode PV2 Error Code {0:0,128:128,130:130,256:256,384:384}
pv2WarningCode PV2 Warning Code {0:0}
batErrCode Battery Error Code {0:0,4:4,8:8}
bpType Batterypack Type {0:no battery,1:secondary pack,2:primary pack,3:primary pack}
batWarningCode Battery Warning Code {0:0}
llcErrCode llc Error Code {0:0,1:1}
llcWarningCode llc Warning Code {0:0}
wirelessErrCode Wireless Error Code {0:0}
wirelessWarnCode Wireless Warning Code {0:0}
pv1Status PV1 Status {1:1,2:2,3:3,4:4,6:6,7:7}
pv2Status PV2 Status {1:1,2:2,3:3,4:4,6:6,7:7}
batStatus Battery Status {5:5}
llcStatus llc Status {1:idle,2:starting/check logic,3:3,5:5,6:6}
invStatus Inverter Status {1:synced/idle,2:starting/check inv. logic,6:successful grid connection,11:disconnected}
invRelayStatus Inverter Relay Status {0:on,8:8,16:16,17:17,18:18,24:24}
pv1RelayStatus PV1 Relay Status {0:0}
pv2RelayStatus PV2 Relay Status {0:0}
invOnOff Inverter OnOff: {0:0,1:1}

string

State Name
installCountry Install Country
installTown Install Town

energy

number

State Min Max Unit Mult Name
watth1 0 6000 Wh 1 Energy to house loads
watth2 0 6000 Wh 1 Energy to smart plugs
watth3 0 6000 Wh 1 Energy to battery
watth4 0 6000 Wh 1 Energy from battery
watth7 0 6000 Wh 1 Energy from solar PV1
watth8 0 6000 Wh 1 Energy from solar PV2
watth16 0 6000 Wh 1 Energy 16
watth17 0 6000 Wh 1 Energy 17
watth18 0 6000 Wh 1 Energy 18